246 research outputs found

    Non-visual overviews of complex data sets

    Get PDF
    This paper describes the design and preliminary testing of an interface to obtain overview information from complex numerical data tables non-visually, which is something that cannot be done with currently available accessibility tools for the blind and visually impaired users. A sonification technique that hides detail in the data and highlights its main features without doing any computations to the data, is combined with a graphics tablet for focus+context interactive navigation, in an interface called TableVis. Results from its evaluation suggest that this technique can deliver better scores than speech in time to answer overview questions, correctness of the answers and subjective workload

    A study of uncertainty models in a reverberation chamber at NIST

    Get PDF
    The reverberation chamber has become a good alternative for over-the-air (OTA) testing of small antennas. Here the uncertainty of total radiated power measurements is evaluated for a reverberation chamber at National Institute of Standards and Technology (NIST), Boulder, Colorado. A procedure for measuring the uncertainty based on the standard deviation of nine different antenna orientations in the RC has been used

    Planar Dual-Mode Horn Array with Corporate-Feed Network in Inverted Microstrip Gap Waveguide

    Get PDF
    The gap waveguide technology was recently introduced as an alternative to hollow waveguides and substrate integrated waveguides for millimeter-wave applications. This paper presents the design of a 4 x 4 planar dual-mode horn array with low loss corporate feed network realized by using an inverted microstrip gap waveguide. The dual-mode horns are compact and designed to reduce the power losses in grating lobes. It is because the diameters of the horn apertures are larger than two wavelengths to allow more space for the feed network and thereby lower conductive losses. The measurements show very good agreement with simulations, with 10% bandwidth of the return loss, 25 dBi realized gain and about 60% aperture efficiency

    Evaluation of multi element antennas in reverberation chamber

    Get PDF
    This paper focuses on the latest advances in the use of reverberation chambers for active device testing. Contained are description and comparison of different figure-of-merits that are applicable to multi element antennas, with a specific focus on LTE devices with MIMO capability. There are two new parameter concepts introduced: Modified Total Isotropic Sensitivity measurements to include MIMO signaling, and a Throughput Threshold Level for simplified quantification of data bit throughput measurement results

    Preoperative CT angiography reduces surgery time in perforator flap reconstruction

    Get PDF
    The use of perforator flaps in breast reconstructions has increased considerably in the past decade. A disadvantage of the perforator flap is difficult dissection, which results in a longer procedure. During spring 2006, we introduced CT angiography (CTA) as part of the diagnostic work-up in perforator flap reconstructions to visualise each perforator more accuratety. The main objectives were to reduce surgery time and the number of complications. A chart review was conducted 1 year after CTA introduction to investigate if these objectives were met. Materials and methods: Patients with a deep inferior epigastric perforator (DIEP) flap who underwent preoperative analysis through CTA were retrospectively evaluated. The population Results: One hundred and thirty-eight DIEP breast reconstructions were done; 70 underwent preoperative CTA analysis, and 68 had preoperative Doppler investigation. Surgery time in the CTA group was significantly lower (P <0.001) than in the control group, 264 min (SD +/- 62) versus 354 min (SD +/- 83), respectively. There was a tendency for fewer complications in the CTA group compared with the control group. All flaps were successful in the CTA group. In the control group, one flap failed and partial necrosis occurred in three flaps. The differences were not statistically significant. Conclusions: Preoperative CTA in the assessment of vascular anatomy during perforator flap reconstruction was safe and reliable. It helped reduce surgery time, and may prevent the number of postoperative complications. (C) 2008 Published by Elsevier Ltd on behalf of British Association of Plastic, Reconstructive and Aesthetic Surgeons

    ACBAR: The Arcminute Cosmology Bolometer Array Receiver

    Full text link
    We describe the Arcminute Cosmology Bolometer Array Receiver (ACBAR); a multifrequency millimeter-wave receiver designed for observations of the Cosmic Microwave Background (CMB) and the Sunyaev-Zel'dovich effect in clusters of galaxies. The ACBAR focal plane consists of a 16-pixel, background-limited, 240 mK bolometer array that can be configured to observe simultaneously at 150, 220, 280, and 350 GHz. With 4-5' FWHM Gaussian beam sizes and a 3 degree azimuth chop, ACBAR is sensitive to a wide range of angular scales. ACBAR was installed on the 2 m Viper telescope at the South Pole in January 2001. We describe the design of the instrument and its performance during the 2001 and 2002 observing seasons.Comment: 59 pages, 16 figures -- updated to reflect version published in ApJ

    Full-wave invisibility of active devices at all frequencies

    Full text link
    There has recently been considerable interest in the possibility, both theoretical and practical, of invisibility (or "cloaking") from observation by electromagnetic (EM) waves. Here, we prove invisibility, with respect to solutions of the Helmholtz and Maxwell's equations, for several constructions of cloaking devices. Previous results have either been on the level of ray tracing [Le,PSS] or at zero frequency [GLU2,GLU3], but recent numerical [CPSSP] and experimental [SMJCPSS] work has provided evidence for invisibility at frequency k≠0k\ne 0. We give two basic constructions for cloaking a region DD contained in a domain Ω\Omega from measurements of Cauchy data of waves at \p \Omega; we pay particular attention to cloaking not just a passive object, but an active device within DD, interpreted as a collection of sources and sinks or an internal current.Comment: Final revision; to appear in Commun. in Math. Physic

    Perceived study-induced influence on the control group in a randomized controlled trial evaluating a complex intervention to promote psychosocial well-being after stroke: a process evaluation

    Get PDF
    Background A commonly applied control condition in trials evaluating complex interventions in rehabilitation research is “usual care.” The main challenge is to ensure that the control group receives genuine usual care as delivered in everyday clinical practice. The assessment interviews and dialogues with the data collectors may influence the control group participants’ reflections on their condition and adjustments. This represents a threat to the internal validity of the trial. Thus, the aim of this study was to explore the perceived study-induced influence of assessment interviews on the adjustment of the members of a control group in a randomized clinical trial. The aim of the trial was to test a dialogue-based psychosocial intervention aiming at promoting the psychosocial well-being and adjustment of stroke survivors. Methods Fifteen participants in the control group of a multicenter stroke rehabilitation trial participated in narrative semi-structured interviews. Ricoeur’s interpretation theory guided the analysis. Results The perceived study-induced influence of the assessment interviews on the adjustment process of members of the control group varied considerably. The results demonstrated that the assessment interviews facilitated some participants’ feelings of control and their ability to cope. Other participants’ statements indicate that they relied on their existing personal capacity to cope and adjust and that the assessment interviews did not make any difference either on their coping ability or on their process of adjustment. Five themes were identified that described the perceived study-induced influence of the assessment interviews in the control group. The themes illustrated that the assessments served as a safety net, enhanced awareness and understanding, encouraged seeking support, allowed the opportunity to vent disappointment, or did not make any difference either way. Conclusions RCT assessment interviews may influence the adjustment process and represent a serious problem in measuring interventions over time in trials of complex interventions in rehabilitation research. To uphold rigor and stringency, the usual care control conditions should be thoroughly assessed and described. Informing participants only about the treatment they were allocated to receive might counteract the potential to dilute the difference between the two arms of the trial
    • 

    corecore